Network requirements, 1 fepim module specifications, 2 fe-100fx – Cabletron Systems 7H02-06 User Manual
Page 15: Chapter 2 network requirements, 1 fepim module specifications -1 2.2 fe-100fx -1, Appendix a
2-1
CHAPTER 2
NETWORK REQUIREMENTS
Before installing Cabletron Systems 7H02-06 Module, review the
network requirements outlined in this chapter. All requirements
included in this chapter should be met to ensure satisfactory
performance of the 7H02-06 Module. Failure to do so may result in
unsatisfactory network performance.
Appendix A
2.1 FEPIM MODULE SPECIFICATIONS
This module uses 5 RJ45 connectors and one Fast Ethernet Port
Interface Modules (FEPIMs) to provide front panel cable
connections. The FEPIMs are user-installable. See Section
3.2
INSTALLING FEPIMS.
2.2 FE-100FX
The FE-100FX provides a multimode fiber connection, using a SC
type connector. The specifications for this device are listed in
Table 2-1.
Table 2-1. FE-100FX Specifications
Parameter
Typical
Value
Worst
Case
Worst
Case
Budget
Typical
Budget
Receive
Sensitivity
-30.5 dBm
-28.0 dBm
—
—
Peak Input
Power
-7.6 dBm
-8.2 dBm
—
—