Filling a Type 1 Cylinder Valve

Example A: shows a CGA-510 POL fitting.

Example B: shows using a Type 1 POL fitting.

When using a cylinder exchange, be sure the

exchanged cylinder is a Type 1 cylinder; a 510
POL cylinder will not fit a Type 1 regulator.

F

ILLING AND

P

URGING

T

YPE

1 L.P. G

AS

C

YLINDERS

DANGER! Purging and filling of L.P. Gas

cylinders must be performed by personnel
who have been thoroughly trained in accept-
ed L.P. gas industry procedures. Failure to
follow this instruction may result in explo-
sion, fire, severe personal injury, or death.

IMPORTANT: Purge new cylinders before fill-

ing. This tank is easily filled with a standard
CGA 510 POL filling connection.

The L.P. gas cylinder has a Type 1 cylinder

valve with a back-check module in its outlet that
will not permit gas to flow until an evacuation
device is installed. To purge the L.P. gas cylin-
der, the back-check module must be opened
with an evacuation device.

P

URGING AND

E

VACUATION

D

EVICES FOR

L.P. G

AS

C

YLINDER WITH

T

YPE

1 C

YLINDER

V

ALVES

A. Hose-end valve with a bleed port: Purging

can be accomplished using a hose-end valve
containing a bleed port, which also allows for
evacuation without the use of an adapter.

B. Hose-end valve without a bleed port: When

a hose end valve does not have a bleed port, a
separate device must be used for evacuation.

C. Purging using a Type 1 connection: L.P.

gas cylinder evacuation can be accomplished
during each purging by using a Type 1 connec-
tion. The Type 1 valve outlet has an 1 5/16"
external ACME right-hand thread that will
accept this connection.

CAUTION: After purging or filling an L.P. gas

cylinder, do not insert a POL plug into the valve
outlet. Insertion of this plug will prevent the
back-check from closing. Use ONLY the provid-
ed cap and strap attached to the outlet. Close
the cylinder valve knob before returning the
cylinder to the customer.

For proper purging procedures in the U.S.A.

refer to: Safety Bulletin NPGA #133, “Purging
L.P. Gas Cylinders,” and Safety Bulletin NPGA
#130, “Recommended Procedures for Filling
Cylinders.”

DANGER: Do not fill an L.P. gas cylinder

beyond 80% full. If this information is not
followed exactly, a fire causing serious
injury or death may occur.

7

Example A

Example B