The engine manufacturer has established an excellent world-wide
engine service organization; engine service is available from a
nearby authorized dealer or distributor; check the yellow pages of
the telephone directory under “engines,” or ask the dealer from
whom you purchased the power plant.
The rated power of each engine-generator is limited by the
temperature, altitude and all other ambient conditions specified
by the engine manufacturer. Engine power will decrease 3-1/2%
for each 1000 ft. above sea level, and will decrease an additional
1% for each 10 degrees Fahrenheit above 60 degrees Fahren-
heit.
UNPACKING INSTRUCTIONS
** NOTICE **
When unpacking the generator set, be sure to inspect it carefully
for freight loss or damage. If loss or damage is noted at the time
of delivery, require that the person making the delivery make
note of the loss or damage on the freight bill, or affix his signa-
ture under the consigner’s memo of the loss or damage. Contact
the carrier for claim procedures.
When loss or damage is noted after delivery, segregate the
damaged material, and contact the carrier for claim procedures.
“Concealed Damage” is understood to mean damage to the
contents of a package which is not in evidence at the time of
delivery by the carrier, but which is discovered later. The carrier
or carriers are responsible for merchandise lost or damaged in
transit. The title to goods rests with the consignee when
generators are shipped fob factory, and only the consignee can
legally file a claim.
**** CAUTION ****
EQUIPMENT DAMAGE - The PSS20000LS, PSS35000 and the
PSS70000 are shipped with oil, and a 50/50 mix of coolant. Be
sure to check all fluid levels before operating. See engine
manufacturer’s instruction manual for recommended oil require-
ments before initial starting.
UNPACKING:
1.
Carefully remove the carton.
2.
After inspecting the engine-generator for external physical
damage, check for the following items packed inside the carton.
a.
Owner’s manual, wiring diagram, and parts list.
b.
Engine manufacturer’s instruction manual.
3.
Remove main frame hold down bolts, (4).
4.
Unit can now be lifted from shipping rails.
** NOTICE **
These unit will automatically transfer if a power outage occurs
while running in an exercise mode.
SPECIFICATIONS
GENERATOR
MODEL
WATTS
VOLTS
AMP
H Z
PH
RPM
PSS20000LS
20,000
120/240
83
60
1
1800
PSS20000LS-4
20,000
120/208
69
60
3
1800
PSS20000LS-17
20,000
120/240
60
60
3
1800
PSS20000LS-18
20,000
277/480
30
60
3
1800
PSS35000
30,000
120/240
125
60
1
3600
PSS35000-4
35,000
120/208
121
60
3
3600
PSS35000-17
35,000
120/240
105
60
3
3600
PSS35000-18
35,000
277/480
53
60
3
3600
PSS70000
65,000
120/240
271
60
1
1800
PSS70000-4
70,000
120/208
243
60
3
1800
PSS70000-17
70,000
120/240
210
60
3
1800
PSS70000-18
70,000
277/480
105
60
3
1800
*Derate 10% for Natural Gas operation. Derate 3.5% per
1000 feet elevation above sea level.
FUEL CONSUMPTION
NG (1,000 BTU/CU FT) L.P. VAPOR (2,520 BTU/CU FT)
MODEL
CF/HR
BTU/HR
#/HR
GAL/HR
CF/HR
BTU/HR
PSS20000
365
365,00
13.7
3.3
117
295,200
PSS35000
540
540,000
28.5
6.7
243
612,000
PSS70000
940
940,000
48.9
11.5
417
1,005,222
L.P. TANK SIZING
Minimum required L.P. Tank size for L.P. Vapor withdrawal
operating at various outside temperatures given in degrees
Fahrenheit (Celsius)
TANK TEMPERATURE
MODEL
60 F(16 C) 30 F(0 C) 0 F(-18 C) -20 F(-29 C)
PSS20000
100 Gal
150 Gal
500 Gal* 1500 Gal*
PSS35000
160 Gal.
300 Gal.
1000 Gal.* 2000 Gal.*
PSS70000
500 Gal.
1000 Gal. 2500 Gal.* 9000 Gal.*
*Recommend liquid withdrawal at these temperatures.
ENGINE SPECIFICATIONS:
Refer to engine operating and maintenance instructions
** NOTICE **
Regarding Engines - This manual covers the generator portion
of these units. See the separate engine instruction manual for
engine-related problems, detailed engine information and
engine warranty.
** CAUTION **
EQUIPMENT DAMAGE - Be sure to check the engine oil level
frequently as specified in the engine manual.