beautypg.com

Winco 2-Wire Conversion Instructions ULPSS8B2W/E User Manual

Page 3

background image

WINCO INC.

225 S. CORDOVA AVE.

LECENTER, MN 56057

507-357-6821

SERVICE DEPT.

507-357-6831

wincogen.com

the wiring harness through the hold and

pushing the controller back into position.

12. Re-install the 6 torx screws “G”.

13. Re-install the plastic grommet “H”.

14. Re-connect the wiring harness “D”.

15.

Connect 2-wire white connector “E”

to the matching connector “I” on the

bottom of the new controller. **

** If left disconnected the unit will

start then shut down.

16. Replace the circuit breaker cover

panel and re-install the 2 bolts “B”.

17. Replace rear door.

18. Replace left side door.

19. Re-attach the battery cable if done so earlier.

20. Replace the right side access panel and roof.

21. Remove the operators manual part # 60706-210 for model ULPSS8B4W/E

from the literature package and replace it with operators maual part # 60706-211 for

model ULPSS8B2W/E. This replacement manual contains the proper information for

installation and operation of a 2-wire auto start system. The customer must have this

manual in order to start and operate the unit after the installation of the new engine

control.

22. Replace the rear door.

23. Using the new operators manual, 60706-211, this unit is now ready to be in-

stalled as a standard 2-wire start system. This generator set will now work with any

transfer switch that provides a ‘dry’ relay closure for a start/run signal.

If you have any problems or need assistance,

feel free to contact the WINCO Service

Department at 507-357-6831.

60710-125-11078-01