beautypg.com

Troubleshooting – WaterChef C7000 User Manual

Page 9

background image

www.waterchef.com

7

CONDITION

White sediment is in my filtered water.

REASON

There is a presence of calcium carbonate in

your main water supply. This condition will

occur any time the filtered water is boiled

or frozen and then melts.

SOLUTION

This condition is normal – no action is

required. However, you may choose to

strain the white sediment.

CONDITION

Ice cubes appear cloudy in the center.

REASON

Minerals such as calcium and magnesium

that are present in your water supply

collect in the center of ice cubes when

the water is frozen.

SOLUTION

No action is required. Your System is

specifically designed to leave beneficial

trace minerals in your water.

CONDITION

The YELLOW Lamp on the Intelligent

Monitor

is flashing.

REASON

Your Filter Cartridge is reaching the end

of its rated capacity and will need to be

replaced soon.

SOLUTION

Purchase a new, NSF certified WaterChef

®

CR70 Filter Cartridge. For the location of

the reseller nearest you, call WaterChef

Customer Care at 1.800.879.8909 (int’l

+1.775.359.9500). Once the RED Lamp

begins flashing, it’s time to install a new

CR70 Cartridge and Battery (included).

CONDITION

Diverter Pin is sluggish or does not fully

return to the “off” position after being

in service for a while.

REASON #1

There could be a lack of lubricant on the

shaft of the Diverter Valve.

SOLUTION #1

Remove the Diverter Valve from the kitchen

faucet. Press petroleum jelly into opening

on the Diverter Valve. Work the Diverter Pin

in and out until a smooth motion is restored.

REASON #2

Hard water (water with high content of

dissolved minerals) has caused a buildup

in the Diverter Valve.

SOLUTION #2

Soak Diverter Valve in vinegar for several

hours to remove buildup. Then rinse

Diverter Valve with warm water. Press

petroleum jelly into opening on the Diverter

Valve and work the Diverter Pin in and out

until a smooth action is restored. Replace

rubber washer and reconnect the Diverter

Valve to the kitchen faucet.

CONDITION

Filtered water is flowing slowly from

the System.

REASON

Excessive amounts of particles in the water

supply may cause premature plugging of

Filter Cartridge. This condition may occur

before the RED Lamp begins to flash.

SOLUTION

Filter Cartridge must be replaced due to

poor water quality conditions in your area.
NOTE: Battery MUST be replaced at time

of Cartridge replacement. (CR70 Filter

Cartridge includes a new Battery.)

TROUBLESHOOTING