Wiring diagram - tr008 f-6 blower assembly, Service hints continued – Vogelzang TR008 User Manual
Page 18

Page 18 | DURANGO™
Vogelzang International Corp.
TR008-96 | 20120425.0
WIRING DIAGRAm - TR008 F-6 blOWER ASSEmblY
When ordering missing or replacement parts, always give the
Model Number of the stove,
Part Number, and Part Description. Use the illustrations and part lists provided to identify parts.
Contact us at
616-396-1911 to order parts.
DOOR gASkET REPLACEMENT
CAUTION: DO NOT OPERATE A STOVE ThAT
IS MISSINg DOOR gASkET MATERIAL. OVER
FIRINg AND UNSAFE OPERATINg CONDI-
TIONS MAY RESULT.
PROCEDURE:
1. Ensure appliance is not in operation and is thor-
oughly cooled.
2. Remove old door gasket and clean channel.
3. Using an approved, high temperature gasket ce-
ment, apply a thin coat in bottom of channel.
SERVICE HINTS continued...
4. Starting at hinge side of door, work gasket into
channel around door unit, end butt and trim to
length.
5. Close door and allow three to four hours for cement
to set before firing appliance.
BLOwER MAINTENANCE
The blower is maintenance free other than periodic
cleaning. Lightly vacuum motor and air inlet to keep free
of dust and dirt.
NOTICE: ANY REPLACE-
MENT wIRINg MUST hAVE
E q U I VA L E N T I N S U L A -
TION AND TEMPERATURE
RATINg (105°C).
CAUTION: MOVINg PARTS CAN CAUSE
INjURY. DO NOT OPERATE wITh COVER
REMOVED.
DANgER: ShOCk hAzARD. DISCONNECT
POwER SOURCE BEFORE INSTALLATION
AND whENEVER SERVICINg BLOwER