beautypg.com

Operating continued... service hints – Vogelzang TR008 User Manual

Page 15

background image

TR008-96 | 20120425.0

www.vogelzang.com

DURANGO™

| Page 15

coal bed does not obstruct the air inlet. Do not load
fuel to a height or in such a manner that it creates
a hazard when opening the door.

4. Close the feed door and secure tightly.
5. Adjust the air inlet control as described above.
6. Empty ashes regularly. Do not allow ashes

to pile up (see Safety Instructions #14 on
page 2.)

7. Properly dispose of hot ashes (see Safety

Instructions, item #14 on page 2.)

8. Do not over fire the stove (over firing is when

any par t of the stove exterior or chimney
connections glow).

CAUTION: DO NOT OVER FIRE APPLIANCE.
YOU ARE OVER FIRINg IF ThE ChIMNEY
CONNECTORS OR STOVE gLOwS RED. CLOSE
ThE DOOR AND ShUT DAMPER IMMEDIATELY
TO REDUCE ThE AIR SUPPLY AND SLOw
DOwN ThE FIRE.

CAUTION: SLOw BURNINg FIRES AND
EXTENDED USE MAY CAUSE EXCESSIVE
CREOSOTE BUILDUP. IgNITION OF CRE-
OSOTE OR OVER FIRINg MAY CAUSE A
ChIMNEY FIRE. ChIMNEY FIRES BURN
E X T R E M E LY h OT A N D M AY I g N I T E
SURROUNDINg MATERIALS. IN CASE OF A
ChIMNEY FIRE CALL ThE FIRE DEPARTMENT
IMMEDIATELY.

BLOwER OPERATION

If your stove is equipped with the blower

attachment, follow these instructions for optimal opera-
tion.

LOW (door air control is fully closed to 1/4 open):

Turn the fan on 30 minutes after fuel has been added
and set the fan speed at low.

MEDIUM (door air control 1/4 to 3/4 open): Wait

15 minutes after fuel has been added and set the fan
speed control at high.

HIGH (door air control wide open): Wait 5 minutes

after fuel has been added and set the fan speed at high.

OpERATING continued...

SERVICE HINTS

continued on next page

CREOSOTE – FORMATION AND NEED FOR
REMOVAL

CauTION: RISK OF FIRE when wood is burned
slowly, it produces tar and other organic vapors,
which combine with expelled moisture to form
creosote. The creosote vapors condense in the
relatively cool chimney flue of a slow-burning
fire. As a result, creosote residue accumulates
on the flue lining. when ignited this creosote
makes an extremely hot fire.

The chimney connector and chimney should
be inspected at least once every two months
during the heating season to determine if a
creosote buildup has occurred.

If creosote has accumulated (3mm or more)
it should be removed to reduce the risk of a
chimney fire.

Failure to remove creosote may result in ignition

and may cause a house/building fire. Creosote may be
removed using a chimney brush or other commonly
available materials from your local hardware retailer.

Chimney fires burn very hot. If the unit or chimney

connector should glow red, reduce the fire by clos-
ing the inlet air control and immediately call the fire
department.

CAUTION: A ChIMNEY FIRE MAY CAUSE IgNI-
TION OF wALL STUDS OR RAFTERS whICh
wERE ASSUMED TO BE A SAFE DISTANCE
FROM ThE ChIMNEY. IF A ChIMNEY FIRE
hAS OCCURRED, hAVE YOUR ChIMNEY IN-
SPECTED BY A qUALIFIED EXPERT BEFORE
USINg AgAIN.

A fire in the firebox may be smothered by pouring

a large quantity of coarse salt, baking soda, or cool
ashes on top of the fire.

PREVENTINg CREOSOTE BUILDUP

1. Creosote will inevitably form in your chimney and

connector pipe. Following these steps will help
reduce the rate of build up.

2.

BURN ONLY SEASONED wOOD that has dried
for at least one year.

3. Burn hardwood rather than softwood. Hardwood

is denser or heavier wood and burns hotter.

4. Do not attempt to burn (or mix in) green or wet

wood. The use of green or wet wood will cause a
rapid build up of creosote. Wood that hisses, sizzles
and blackens without igniting in five minutes must
be considered too wet to burn.