know the number. But we still will, just in case. Then
your own selected regular password will work and as long as
you don't forget it, your ok.
Blenders are pre-programed with two normal passwords;
(22222) is the default password for the PROGRAM mode,
(11111) is the default password for the MANUAL mode. You
can alter these passwords to any 5 digit number, but you
must know the current PROGRAM password to change it. If for
some reason the password has been altered and you can not
remember it, we have a special "backdoor" password that will
let you in no matter what. For obvious reasons, we do not
provide that password in this manual. You must call us.
However, there is a problem. If the wrong person in your
factory obtains this password, then he will always have
access to the Program mode of the blender no matter what.
Now, with this star function, you have the option to select
from 10 different "backdoor" passwords. If your current
"backdoor" password is known to the wrong person, you can
call us for a new one. We will not give these backup
passwords to just anyone. In fact, since only I know them,
it is not that easy to obtain these numbers.
To activate a new "backdoor" password, you will enter a
number from 00000 to 00009 using this star function. each
number activates a different password. entering 0 activates
the current backdoor password, the one we have used for over
10 years. For a new one, call us and talk with someone you
know here in the office and they will supply a number from 1
to 9, and the associated new "backdoor" password.
After this new "backdoor" password is selected, you can
safely change the regular password to one only you know, and
use that in normal production. No one will be able to use
the backdoor to get in. If you forget your regular
password, and you also forget which backdoor password you
selected, then we will work with you and go through the
entire list to find the one that works.
*87 Press (*,8,7) to set flag for operation in a VOLUMETRIC
mode. With this flag ON (VOLUMETRIC mode), the load cells
are completely ignored. Error correction and rate
recalibration does not take place. The unit functions like
a volumetric feeder without checking or correcting for
errors. Since load cell readings are ignored, this flag
allows operation even if the load cells become damaged.
Dispense times will be based entirely on the WT and TI
parameters.
Use the * key to toggle flag ON or OFF.
Power On will always set this flag to OFF.
Press EXIT when desired flag status is displayed.
*88 Press (*,8,8) to force a documented printout of the display
on the controller front. DATE, TIME, Machine number, and
display will print:
Page 42