We program every controller to match the model it is shipped with.
If your controller DOES NOT display the correct model (first two digits

only) on power up, follow these instructions.

There are SEVEN basic models of Weigh Scale Blenders. The MODEL number
your unit is set for (first two digits only) is displayed during the
start up sequence every time power is turned on. Disregard the last
digit of your model number when selecting from this list.

The possible models are:
MODEL BATCH WEIGHT WEIGH BIN # DISPENSE LOAD CELL

(GRAMS) DIMENSIONS VALVES RATING

GBM Microblender 400 5 x 5 x 5 high 4 1 @ 3 K
140,131,122,14R 1000 10 x 6 x 6 high 4 1 @ 3 K
220 2000 10 x 10 x 7 high 2 2 @ 3 K
240,24R 2000 10 x 10 x 7 high 4 2 @ 3 K
420,44R 4000 10 x 10 x 10 high 2 2 @ 10 K
440 4000 10 x 10 x 10 high 4 2 @ 10 K
940 9000 16 x 16 x 12 high 4 2 @ 10 K

1840 18000 16 x 16 x 17 high 4 2 @ 20 K

400, 1000 and 2000 gram systems with 3 kg. load cells; weights are
displayed in tenths of grams ( xxxx.x).

4000, 9000, and 18000 gram systems with 10 or 20 kg. load cells;
weights are displayed in full grams ( xxxxx).

If your unit is NOT set correctly to match the hardware you have, you
must change it. To do so:

Turn power on. From the NORMAL mode:

+-------------------------------------------------------+
¦ Press: * Display will say: (PASSWORD) ¦
¦ ¦
¦ Press: 97531 Display will say: (MODEL240) ¦
¦ or whatever model it is set for. ¦
¦ ¦

¦ Press: * To walk through all seven models. ¦
¦ When the model you want is displayed,¦
¦ then: ¦
¦ ¦
¦ Press: EXIT Wait a few seconds. ¦
¦ Unit will reset and restart ¦
¦ as the system you have selected. ¦
+-------------------------------------------------------+

When switching models, all parameter table information is lost and the
new "default" information for this model is loaded from ROM.