beautypg.com

Interface parameters, B.96, D. 8 – VACUUBRAND MZ 2C VARIO User Manual

Page 38: P.no, H.no, R.no

background image

page 38 of 51

Documents are only to be used and distributed completely and unchanged. It is strictly the users´ responsibility to check
carefully the validity of this document with respect to his product. manual-no.: 999034 / 22/04/2008

Interface parameters

The controller CVC 2000

II

is equipped with a serial interface at the rear side of the housing (RS 232C, nine-

pole Sub-D-plug).
☞ Respectively plug-into or remove the cable (cable RS 232C, nine-pole Sub-D) from the interface only if

the equipment is switched off.

☞ The interface is not electrically isolated from the measuring circuit.

☞ For optimal electromagnetic compatibility assemble an interface filter (cat. no.: 638235).

The controller can be operated via serial interface. Measuring results, preselections and the status of the
controller can be read at any time. Controlling via interface is only possible, if the remote operation mode
has been preselected at the controller. During remote operation (”PC” is displayed) the controller can
be operated only via interface, the keys at the controller have no function, the warning triangle is
displayed.

Setting of the interface

Setting of the interface parameters directly at the controller is described below. The factory set values are
underlined.

➨ 1200, 2400, 4800 or 9600 BAUD

➨ 7 data bits odd, 7 data bits even, 8 data bits none, 8 data bits odd, 8 data bits even

➨ no Handshake, XON/XOFF Handshake, CTS/RTS Handshake

➨ remote on, remote off

☞ Unchangeable: Startbit = 1, Stopbit = 1

Press key Mode

▲ during switching on.

☞ The controller switches to the mode to configurate the inter-

face.

BAUD-Rate is displayed.
➨ Press key Mode ▲ or ▼ to select the BAUD rate and con-

firm with key STOP (”96”=9600, ”48”=4800, ”24”=2400,
”12”=1200).

Data bits are displayed.
➨ Press key Mode ▲ or ▼ to select the data bits and confirm

with key STOP.

Parity is displayed.
➨ Press key Mode ▲ or ▼ to select parity and confirm with

key STOP (”no” = no check of parity, ”O” = odd, ”E” = even).

Handshake is displayed.
➨ Press key Mode ▲ or ▼ to select handshake and confirm

with key STOP (”no” = no Handshake, ”HA” = RTS/CTS,
”SO” = XON/XOFF).

Remote is displayed.
➨ Press key Mode ▲ or ▼ to select parity and confirm with

key STOP (”no” = local operation, ”On” = remote operation).

☞ The controller switches to normal operation mode (process

control not active).

+

(mains switch)

Set

b.96

Set

d. 8

Set

P.no

Set

h.no

Set

r.no

This manual is related to the following products: