beautypg.com

Safety during operation, Notice – VACUUBRAND BVC 21 NT VARIO User Manual

Page 6

background image

Documents are only to be used and distributed completely and unchanged. It is strictly the users´ responsibility to check carefully

the validity of this document with respect to his product. Manual-no.: 999157 / 10/12/2009

page 6 of 31

The devices are

not suitable to pump

- unstable substances and substances which react explosively under

impact (mechanical stress) and/or when being exposed to elevated

temperatures without air,

- self inflammable substances,

- substances which are inflammable without air and

- explosive substance

• The devices are

not suitable for pumping substances which may form deposits

inside the pump. Deposits and condensate in the pump may lead to increased

temperatures even to the point of excessing the maximum permitted tempera-

tures! Increased temperatures may cause ignition of inflammable substances be-

ing eventually inside the pump.

• If there is a danger of the formation of

deposits in the pump chamber (check inlet

and outlet of the pump), inspect the pump chamber regularly and clean if neces-

sary.

• The pumps are

not suitable for pumping dust and have no approval for opera-

tion below ground.

If pumping

different substances, it is recommended to purge the pump with air or

inert gas prior to changing the pumped media in order to pump out residues and to

avoid reactions of the pumped substances with each other and with the pump ma-

terials.

Take into consideration interactions and chemical reactions of the pumped

media. Ensure that the materials of the wetted parts are compatible with the pumped

substances, see section ”Technical data”.

Safety during operation

Adopt suitable measures to prevent the release of dangerous, toxic, explosive,

corrosive, noxious or polluting fluids, vapours and gases. In case install an ap-

propriate collecting and disposal system and take protective action for pump and

environment.

If the equipment is used in combination with

hazardous materials (e. g. in med-

ical-microbiological laboratories) check all relevant safety and health require-

ments and determine the applicability of regulatory limitations prior to use if nec-

essary.

Prevent any part of the human body from coming in contact with the vacuum.

Use appropriate safety work materials and methods if necessary, e. g. steam

sterilization, sterilization indicators or germicides. Notes concerning the steriliza-

tion of wetted parts (see ”Technical data”) see section ”Cleaning and decontami-

nating”. It is the user´s responsibility to ensure effective sterilization.

➨ The user must take suitable precautions to prevent any formation of explosive

mixtures in the expansion chamber or in the housing. In case of e.g. a diaphragm

crack, mechanically generated sparks, hot surfaces or static electricity may ignite

these mixtures. Use inert gas for venting if necessary.

Potentially explosive mixtures at the outlet of the pump have to be drained ap-

propriately, sucked off or diluted with inert gas to non-explosive mixtures.

Pay attention to the symbol ”hot surfaces” on the equipment. Adopt suitable

measures to prevent any danger arising from hot surfaces. Allow pump to cool

down before starting maintenance.

NOTICE

This manual is related to the following products: