Setup screens, Style, Att & zero – TruTrak EFIS (8300-056) User Manual
Page 9: Info
TruTrak Flight Systems
7
EFIS Installation Manual
February 2009
8300-056 Rev B
SETUP SCREENS
To enter the setup screen the right knob must be pressed and held until the SETUP shows then press and
release the soft key below SETUP before releasing the right knob. This is the location that the STYLE,
ATT & ZERO, INFO, UNITS, BALL, ALERTS, SPEEDS, & SERIAL Baud rate are set at.
Press and release the right knob to return to the main screen.
STYLE
Select ether ROUND gauge or
RECT tape style airspeed and
altimeter gauges.
Press and release the right knob to
return to the SETUP screen if no
selection pressed.
ATT & ZERO
Click ATT on or off to show aircraft attitude indication on the EFIS
horizon. The attitude can be zeroed for different aircraft by clicking
the ZERO soft key button.
INFO
This button will display the information about all the components that
are connected to the EFIS communication buss, Serial numbers,
Software version, and Model type.
The LEFT KNOB must be clicked to return to the main page.