TROUBLESHOOTING
T
Symptom
No signal output. Main power switch 
is on, but no LED’
s are illuminated.
Solution
 Check AC power source and cord.
 Check fuses (pull fuse drawer under power
cord inlet)
No signal output. Main power switch 
is on and some LED’
s are
illuminated.
 Check status of phantom power.
 Check continuity of mic and electric
instrument cables.
 Check continuity of output cables.
Output signal is distorted. Outputs 
are 
connected
for
balanced
operation.
 Make sure gain is adjusted so that the OL
indicator does not activate during the audio 
program.
 Make sure the high output capability of this
unit is not overloading the device or 
monitoring system to which it is connected -
set GAIN selector to match capability of 
device or monitoring system, then adjust gain 
control according to indications on the Level 
Indicator LED’
s.
 Check continuity of output cable.
 Make sure outputs are not connected to a
load impedance of less than 600 ohms.
Output signal is distorted. Outputs 
are connected for unbalanced 
operation.
 Make sure the minus (-) output signal pins are
connected to the shield and not left 
unconnected. See “Output Cable Connection” 
section.
 Check troubleshooting tips for balanced
operation (above).
Hum can be heard in the audio 
program.
 Disconnect grounding LINK.
 Check continuity of output cables (particularly
shields).
 Disconnect shields on one end of output
cables. Connect grounding LINK.
Channel 1 signal can be heard in 
Channel 2 output - and vice versa.
 Check status of M-S selector. It should be
OFF for individual channel mode and ON for 
Mid-Side mode.
Channel 2 seems to have no output 
when used with Channel 1 as a 
stereo pair
 Check status of M-S selector. It should be
OFF for individual channel mode and ON for 
Mid-Side mode.