TRUE Systems P2 ANALOG User Manual
Page 16
P2
analog
OPERATION MANUAL
16
TROUBLESHOOTING
T
Symptom
No signal output. Main power switch
is on, but no LED’
s are illuminated.
Solution
Check AC power source and cord.
Check fuses (pull fuse drawer under power
cord inlet)
No signal output. Main power switch
is on and some LED’
s are
illuminated.
Check status of phantom power.
Check continuity of mic and electric
instrument cables.
Check continuity of output cables.
Output signal is distorted. Outputs
are
connected
for
balanced
operation.
Make sure gain is adjusted so that the OL
indicator does not activate during the audio
program.
Make sure the high output capability of this
unit is not overloading the device or
monitoring system to which it is connected -
set GAIN selector to match capability of
device or monitoring system, then adjust gain
control according to indications on the Level
Indicator LED’
s.
Check continuity of output cable.
Make sure outputs are not connected to a
load impedance of less than 600 ohms.
Output signal is distorted. Outputs
are connected for unbalanced
operation.
Make sure the minus (-) output signal pins are
connected to the shield and not left
unconnected. See “Output Cable Connection”
section.
Check troubleshooting tips for balanced
operation (above).
Hum can be heard in the audio
program.
Disconnect grounding LINK.
Check continuity of output cables (particularly
shields).
Disconnect shields on one end of output
cables. Connect grounding LINK.
Channel 1 signal can be heard in
Channel 2 output - and vice versa.
Check status of M-S selector. It should be
OFF for individual channel mode and ON for
Mid-Side mode.
Channel 2 seems to have no output
when used with Channel 1 as a
stereo pair
Check status of M-S selector. It should be
OFF for individual channel mode and ON for
Mid-Side mode.