15
incorrect pin used
20 attempts at prepayment using incorrect PIN leads to permanent error code 15 display and machine
blocks. Every correct PIN input resets the counter to zero.
technicain:
Initialize
16
error postage registers
Postal registers R1 – R3 could not be corrected to make R1 + R2 = R3 a true statement. Permanent
error display and machine blocks if
a) R1 < R3 ... Correction possible. Error 16 deleted during new start
b) R1 > R3 ... Correction not possible. Permanent error 16 display
technicain:
17
Incorrect checking sum in the register
1...4.
Incorrect checking sum in the register 1...4. Machine blocks and error code 17 is permanent.
technicain:
1. reset (initialize) machine and verify if error still occur
2. replace mainboard
18
NVRAM error
Permanent error display and the machine blocks.
Data in the NVRAM are saved when:
a.) no action is undertaken with the machine for one minute (the display switches to stand-by, the clock
appears in the display left)
b.) during prepayment, or
c.) when power is shut OFF.
technicain:
Check NVRAM (Service computer);
Replace and initialize
19
Memory comparison error
(RAM & NV-RAM)
Memory comparison error (RAM & NV-RAM) Department accounts, PIN, or machine number (each is
stored 3 times) cannot be automatically corrected. Permanent error code 19 and machine blocks.
technicain:
Initialization program incorrectly terminated?
Initialize
20
wrong pressure roller position
The position of the pressure roller is not correct when the machine is turned ON. (Micro-switch
indicates roller not in at-rest position). The position is also checked after every franking operation.
Permanent error code and machine blocks.
technicain:
check micro-switch
check power supply
shaft with tooth wheel is broken?
Defect belt?
diagnostic-
code
subcode1
subcode2
diagnostic message
remedy
ISS international service support
email: [email protected]
created : 20.11.2007 19:31 Uhr
page 7
T1000