Triner Scale T1000 Error Code User Manual
Page 3
![background image](/manuals/714852/3/background.png)
01
battery error
10 beep tones every time the machine is turned on, and the display constantly shows Service and
battery This indicates it is time for the battery change required after 5 years of service. The machine
can still be used for 3 months or up to 3,000 franks. Then the machine will stop functioning and
generate Error code 01.
The test takes place only when the machine is turned ON. If the battery is older than 6 years when the
machine is turned on, the optimail immediately blocks and goes to Error code 01.
technicain:
- replace mainboard
03
Error occurred when running remote
prepayment software.
1. Initialize and observe machine; If error repeats itself:
2. Replace MC board
04
The speed of the FM is to high
C: Exchange cassette
E: check speed in speed test in service modebad contact between cassette and encoder roller?
06
memory error
The number of memory corrections has exceeded 999. This causes the machine to permanently show
Error 06 and to cease operation.
technicain:
1. Replace memory components and observe machine; If error repeats itself:
2. Replace MC board
08
automatic memory recovery not possible
In the event that data in the registers (R1 – R6) is either incorrectly or incompletely filed when the
machine is turned OFF, a data-restoring procedure occurs automatically the next time the machine is
turned ON. This process is usually successful. Each automatic memory correction is briefly indicated
by the appearance of Error code 08, and a sustained beep when the machine is turned ON. If a
memory correction is not possible (RAM does not
accept the data), Error code 08 is displayed permanently and the machine blocks. All register
correction are counted in the statistics register (refer also to Error code 06).
technicain:
1. Replace memory components and observe machine; If error repeats itself:
2. Replace MC board
09
Defective check-sum (MAC)
1. In OTP countries (like USA, Canada): Replace cliché and operating software
EPROM
2. Initialize and observe machine; If error repeats itself:
3. Replace MC board
diagnostic-
code
subcode1
subcode2
diagnostic message
remedy
ISS international service support
email: [email protected]
created : 20.11.2007 19:31 Uhr
page 3
T1000