Error cliché EPROM
Cliché EPROM not present, defective, or incorrectly installed. IC- and socket markings do not agree or
IC contact legs make no contact.
Permanent Error code 10 and machine blocks.
Check components (all pins good contact, correct position, is it the right component?)
If a new cliché EPROM was just installed and the error is:
10 21, 10 22 or 10 29 indicates the EPROM or its contents do not match this type of machine.
10
2x
Error cliché EPROM
Cliché EPROM not present, defective, or incorrectly installed. IC- and socket markings do not agree or
IC contact legs make no contact.
Permanent Error code 10 and machine blocks.
Check components (all pins good contact, correct position, is it the right component?)
If a new cliché EPROM was just installed and the error is:
10 21, 10 22 or 10 29 indicates the EPROM or its contents do not match this type of machine.
11
hardware error memory µP - CPU
Hardware error in processor memory. Machine blocks with permanent error code displayed.
technicain:
replacement of CPU // mainboard
12
read / write error RAM
First beep phase is long. Machine cannot write into or read from RAM. Machine blocks with permanent
error code 12 displayed.
technicain:
1. Replace memory components and observe machine; If error repeats itself:
2. Replace MC board
13
Memory differences registers R1 - R4
Memory differences in Registers R1 - R4 (postal register) could not be corrected. Permanent error
code 13 displayed.
technicain:
1. Replace memory components and observe machine; If error repeats itself:
2. Replace MC board
14
write error RAM
No RAM could be written
technicain:
1. Replace memory components and observe machine; If error repeats itself:
2. Replace MC board