beautypg.com

Triner Scale TS60-1010 User Manual

Page 7

background image

Assembly Guide

TS60-1010 Platform Scale

5

around the scale, alternating from side to side in order to gradually bring all components
together in a proper fit.

Before final tightening, loosely bolt down the top plate, then fully tighten after the
rail/platform bolts have been secured.


7) Attach and Securely Fasten the Two Guard Rails

Attach both guard rails using the bolts provided. Securely tighten all bolts.


8) Connect All Load Cell Cables Into the Junction Box Terminals

SYNOPSIS:
All load cell cables are numbered near the loose wire end of the cable. All terminal
blocks in the junction box are numbered. Each cable connects to the corresponding
terminal block.

a) Feed Load Cell Cable #1 Into the Junction Box and Connect Wires to the #1
Terminal Block
Feed the load cell wires through strain relief for the #1 terminal block. Following the
wiring diagram in Fig. 7, connect the five wire leads to the terminal block. Securely
tighten the strain relief collar to lock the cable into position.

b) Feed Load Cell Cables 2 – 6 Into the Junction Box and Connect All Wires to the
Terminal Blocks
Following the procedure outlined above, connect all load cell cable wires to the junction
box.

9) Connect the Digital Indicator Cable Lead Into the Junction Box Terminal

SYNOPSIS:
The digital indicator cable has loose wires on one end for connecting into the junction
box. The other end of the cable has a threaded connector that mates to the short cable
attached to the digital indicator.

Feed the digital indicator cable wires through the strain relief for the terminal block.
Following the wiring diagram in Fig. 7, connect the five wire leads to the terminal block.
Securely tighten the strain relief collar to lock the cable into position.

10) Mount the Junction Box

Using the provided screws, mount the junction box to Side Rail #1 as shown in Fig. 8.

Push all excess slack cable back into the exit hole as shown in Fig. 8.

Using the provided screws, securely fasten the junction box cover onto the box.