Vx-2000ds, Cable: awg14 – 18, Bmodel number a – Toa VX-200PS ER User Manual
Page 17

17
[When not using a redundant power system]
Required power is supplied to the system from a single power supply unit. Connect the [+] terminal of Input A
to the [+] terminal of Input B, and the [–] terminal of Input A to the [–] terminal of Input B.
24V
MAX150A
BATTERY POWER IN
( )
( )
( )
230V
50/60Hz 240W
6
1
5
4
3
2
6
1
5
4
3
2
DC POWER OUT (+) MAX 25A (DC 20V-40V)
PS IN (
+
) MAX 25A (DC20V-40V)
DS – SF
FUSE
LINK
THERMISTOR
1,2:PS1
PS IN
5,6:PS3
3,4:PS2
VX-2000DS
28 V
4.8 A
DC POWER IN
CH3
CH1
CH4
CH2
PA OUT (SP LINE)
C
H
CH1
C
H
CH2
C
H
CH3
C
H
CH4
( )
6
1
5
4
3
2
6
1
5
4
3
2
DC POWER OUT (+) MAX 25A (DC 20V-40V)
PS IN (
+
) MAX 25A (DC20V-40V)
SX-2100AI
SX-2100AO or SX-2000AO
(The figure below shows the SX-2100AO.)
SX-2000SM
SX-2000CI
SX-2000CO
VP-2064, VP-2122, VP-2241, or VP-2421
4P removable terminal plug
(supplied with the SX-2000SM, SX-2100AI,SX-2000AO,
SX-2100AO, SX-2000CI, and SX-2000CO)
(DC power input terminal)
(DC power input terminal)
28 V
4.8 A
DC POWER IN
Cable: AWG14 – 18
Note
When connecting 2 power cables to a single terminal of the removable
terminal plug, use a ferrule terminal with an insulation sleeve to crimp the
cables because such cable conductors could become loose.
Recommended "Phoenix Contact" ferrule terminals for power supply
cables
Crimping tool: CRIMPFOX UD6-4 (made by Phoenix Contact)
Insulation sleeve
Contact section
Insulation sleeve
Contact section
a
l
2
a
1
a
2
l
1
l
2
l
1
b
b
Model Number
a
1
l
1
l
2
AI 1,5-8 BK
AI-TWIN 2 x 1,5-8 BK
6.6 mm
a
2
3.6 mm
14 mm
16 mm
2.3 mm
8 mm
8 mm
a
3.4 mm
b
1.8 mm