Caution – Toa IR-310BC User Manual
Page 4
4
1. Infrared wireless microphone receptacle
When charging the IR-310M microphone,
insert the microphone directly into the
receptacle.
2. Charging indicator
Lights red continuously while charging is in
progress.
3. Full-charge indicator
Lights green once the battery is fully charged.
4. Power input terminal
Connect the supplied AC adapter to this
terminal.
5. marking plate
Shows the Manufacturer’s name, Model
name, and Electrical rating.
[Indicator status table]
Charging indicator (red) Full-charge indicator (green)
Status
Lit
Unlit
Charging in progress
Unlit
Lit
Charging completed
Both indicators light alternately.
Charging failure
(refer to p. 6 "TROUBLESHOOTING.")
4. NOmENCLATURE
CHARGE
FULL
1
2
3
4
5
[Front]
[Rear]
[Bottom]
5. CHARGING
Avoid charging microphones installed with rechargeable batteries
other than the dedicated IR-200BT battery.
Charging any other than the specified battery could result in fire or
personal injury due to battery rupture.
CAUTION
Step 1. Connect the power cord to the AC adapter, then connect the AC adapter to the charger.
Once connected, push the cord into the slot in the charger’s bottom surface to prevent the AC
adapter plug from accidentally slipping out of place. (Refer to “Handling the power cord” in the
figure on the next page.)
Step 2. Insert the AC power plug into an AC outlet.