Step 4. Fix the coaxial cable to the circuit board of

antenna.

1. Remove 3 cable clamp screws.
2. Connect the coaxial cable to the circuit board.
3. Fix the cable with the removed screws.

Step 5. Mount the antenna bottom case on the wall.

Use the supplies wood screws (4 x 25) to fix it to the
wall surface, or supplies machine screws (3.5 x 20) to
fix to the electrical box.

Notes
When installing the YW-4500, be sure the antenna is

more than 30 cm away from the ceiling. It is
recommended that the unit be installed at the height
of 2.4 m or more from the floor.

Set the antenna vertical to the ceiling floor. The

receiving sensitivity of the antenna, when installed
horizontally, is about 6 dB lower than that when
installed vertically. The receiving sensitivity greatly
depends on the installation condition.

Step 6. Replace the top case and retighten the 4 top

case screws removed.

In this case, pay attention to the following points.

The top case should be positioned with its lamp hole

(located on the bottom side) facing downward.

The knob of attenuator switch on the built-in circuit

board should fit in that of top case.

8. SPECIFICATIONS

Note: The design and specifications are subject to change without notice for improvement.

Power Source

7 to 12 V DC (supplied from tuner)

Current Consumption

Under 15 mA

Receiving Frequency

550 to 932 MHz, UHF

Antenna Gain

More than 8 dB (0 dB position)

Attenuator

0 / –10 / –20 dB (selectable)

Output Impedance

75 Ω

Recommended Cable Type

RG-6/U or RG-11/U

Operating Temperature Range

–10 to 50°C

Operating Humidity

30 % to 85 %RH

Weight 270

g

Color Off-white

6. SPECIFICATION OF THE COAXIAL CABLE

7. ATTENUATOR SWITCH SETTING

The attenuator switch is provided to minimize external noises or interference caused when two
or more microphones having the same channel or adjacent channels are used in close proximity
to each other.
The attenuation level can be selected from 0 (factory-preset), –10, and –20 dB positions.
The more the attenuation level increases (antenna sensitivity becomes less), the narrower the
usable area of wireless microphone is.
In the condition that no interference is present, set the attenuator switch of the antenna for 0 dB position.

Cable Type

External Diameter

Max. Length

RG-6/U

8.4 mm

35 m

RG-11/U

10.3 mm

50 m

dB

–10

0

–20

Cable clamp screws

Coaxial cable

Attenuator switch

• Accessories

Wood screw ................................... 2

Machine screw

(for electrical box) ......................... 2

Rubber bushing ............................. 1

More than 30 cm