6.2. Output Connections
● Low Impedance Speaker
● 70V Line Speaker
● 100V Line Speaker
CAUTION!
• Tripartite the 4Ω, 70V and 100V terminals cannot be used at the same time.
- +24V COM 4Ω COM 70V 100V
100V L
Speak
ine
er
- +24V COM 4Ω COM 70V 100V
70V Line
Speaker
4 - 16Ω
Speaker
- +24V COM 4Ω COM 70V 100V
• Impedances indicated at the terminal represent the total speaker system (load) impedances.
Total impedances of 100V line:
Total impedances of 70V line:
· 42Ω
· 21Ω
Be sure to attach the supplied terminal cover after connection completion.
Because high voltage is applied to the speaker terminals, never touch these terminals to
avoid electric shock.
CAUTION
6.3. Example of External Equipment Connections