Equaliser:


LF: +/-15dB @ 80Hz, shelving,

Mid: +/-15dB, swept 150Hz to 7KHz, Q = 0.7,

HF: +/-15dB @ 12KHz, shelving,


“Pre” and “Sidechain” (Compressor) switches.

Metering:


Tube “Drive” LEDs: Variable intensity over 10dB level range, typically corresponding
to 1% to 5% THD.

Tube “Peak” LEDs: Dependant on level and drive, typically corresponding to 10%
THD.

Output “Peak” LEDs: +19dBu on output.

VU Meter: Switchable to Channel A or B, Input or Ouput, and Gain Reduction.

Nominal calibration: 0VU = +4dBu.

+10dB switch calibration: 0VU = +14dBu.

Power Requirements:


Internally set to 230V 50Hz or 115V 60Hz operation,

Detachable IEC power cord,

Power consumption 32VA.

Dimensions:


2U, rack mounting or free-standing.

W x H x D = 483mm x 88mm x 200mm (19.0” x 7.9” x 3.5”), behind front panel.

Shipping weight: 6Kg.

The above specifications are typical values, and do not represent limits for any particular unit.