beautypg.com

Installation requirements, Product dimensions, Gas pressure regulator – Sure Heat 2008 Amana AM27 User Manual

Page 25: Gas supply requirements, Burner requirements for high altitude

background image

Product Dimensions

53.625”

(136.3cm)

45”

(114.4cm)

33.875”

(86.1cm)

27”

(68.8cm)

13.125”

(33.4cm)

21”

(53.3cm)

20.875”

(53.0cm)

Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes and ordinances. In the absence of local codes,

installation must conform with American National Standards Institute, National Fuel Gas Code ANSI Z223.1 -

latest edition or CAN/CGA B149.1 - latest edition.
IMPORTANT: Grill must be connected to a regulated gas supply. Refer to the model/serial rating plate for in-

formation on the type of gas that can be used. If this information does not agree with the type of gas available,

check with your local gas supplier.
The model/serial number rating plate is located inside the left door of the grill cabinet. See the top illustration.

A

A. Model/serial number plate

Gas Pressure Regulator

The gas pressure regulator supplied with this grill must be used. The inlet (supply) pressure to the

regulator should be as follows for proper operation:

LP Gas:

Operating pressure: 11" (27.9 cm) WCP

Inlet (supply) pressure: 11" to 14" (27.9 cm to 35.5 cm) WCP Contact local gas supplier if you are

not sure about the inlet (supply) pressure.

Gas Supply Requirements

25

INSTALLATION REQUIREMENTS

Burner Requirements for High Altitude

Input ratings shown on the model/serial rating plate are for elevations up to 2,000 ft (609.6 m).

For elevations above 2,000 ft (609.6 m), ratings are reduced at a rate of 4% for each 1,000 ft (304.8

m) above sea level. Orifice conversion is required. See “Assistance or Service” section to order.