Introduction, Installation, Package contents – StarTech.com 110VDSLEXTEU User Manual
Page 4: Hardware installation
Instruction Manual
1
Introduction
Package Contents
• 2 x 110VDSLEXT/GB/EU units
• 2 x RJ-45 to VDSL Cable
• 2 x Power Adapter
• Instruction Manual
Installation
Hardware Installation
1. Install one of the 110VDSLEXT / GB / EU units with all four of the DIP switches set to
the upward (OFF) position. This places the unit in CO mode.
2. Install the second 110VDSLEXT / GB / EU unit with DIP switches 2 through 4 set to
the upward (OFF) position and DIP switch 1 set to the downward position (ON).
This places the unit in CPE mode.
3. Plug the DC power adapter into the port on the rear panel of the units, and then
into an available AC outlet.
4. Plug in an RJ45 Ethernet cable to the RJ45 port on the 110VDSLEXT / GB / EU units.
Connect the other end of the cables to your Ethernet devices.
5. Plug a phone cable into the VDSL port of the 110VDSLEXT/GB/EU. Connect the
other end of the cable into the opposing 110VDSLEXT/GB/EU unit.
6. Optional: Configure DIP switches 2 through 4 as necessary (see DIP Switch Settings
section). Leave DIP switch 1 alone, as one unit should always be set to CO mode
while the other is CPE mode.