Beep codes – StarTech.com SV565UTP User Manual
Page 15
Instruction Manual
12
Beep Codes
Some of the keyboard command sequences you issue to the Remote Unit have
multiple possible settings. The Unit will beep to indicate what setting you have
selected for the command you issued. (A short beep followed by a long beep indicates
an invalid command.)
[Ctrl] - [Ctrl] - [Alt]+[E] (Compatibility Mode)
1 beep: disabled
2 beeps: enabled
[Ctrl] - [Ctrl] - [F11] (Remote Image Quality Adjustment)
1 beep: 0 ~ 100 feet (0 ~ 30 meters) of UTP cable length
2 beeps: 100 ~ 200 feet (30 ~ 60 meters) of UTP cable length
3 beeps: 200 ~ 300 feet (60 ~ 90 meters) of UTP cable length
4 beeps: 300 ~ 400 feet (90 ~ 120 meters) of UTP cable length
5 beeps: 400 ~ 500 feet (120 ~ 150 meters) of UTP cable length
[Ctrl] - [Ctrl] - [F4] (Typematic Rate)
1 beep: 6 characters/sec.
2 beeps: 12 characters/sec.
3 beeps: 20 characters/sec.
4 beeps: 30 characters/sec.
Note: Commands described in the [Key] - [Key] format are keys that must be pressed
in order on the keyboard. Commands described in the [Key]+[Key] format must be
pressed simultaneously.
Note: If the Num Lock, Caps Lock, and Scroll Lock lights are flashing in unison on the
keyboard, the other Unit has control of Computer A. You will not be able to use A until
the other Unit releases access to that computer.
Note: If the Extender is operating in Compatability Mode ([Ctrl] - [Ctrl] - [E] hotkey
sequence), you must enter [Ctrl] - [Ctrl] - [E] - [E] to access port E on the attached KVM
switch.