beautypg.com

Appendix, Print line output data items – Sonics GXL User Manual

Page 38

background image

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

I N S T R U C T I O N M A N U A L • M O D E L G X L P O W E R S U P P LY

36

A P P E N D I X

Item 1: Using the first line of the sample listing above, item 1 is the

“Customer Resettable Counter” (CRC). It is located at position 1 through

position 6 so the value of 005647 indicates that the last cycle was weld

number 5647 since the last time it was reset to 0 (see page 19).

005647

00.48 sec 0.025 in 000130 J 045 %Pmax Alarms T:-- D:-- E:-- J06 -----

Item 2: The second item sent is the actual weld time from the last cycle –

the time that the ultrasonic generator was running. So 00.48 means that the

generator was ON for .48 seconds. If the weld cycle finished its programmed

weld time, then the following “sec” would have been transmitted as upper

case letters or “SEC.” The “sec” is lower case so the weld cycle was

terminated through some other parameter. The time data is located at

positions 8 through 12 and includes the “.” at position 10. The “sec” label is

located at position 14 through position 16. Space characters are located at

positions 7, 13 and 17.

005647

00.48 sec

0.025 in 000130 J 045 %Pmax Alarms T:-- D:-- E:-- J06 -----

Item 3: Next is the distance data and it may be presented in Metric or

English units (the label) which will change the location of the decimal

character. In the sample, it is sent as 0.025 in. If the system were set for

Metric units, the line would be 00.63 mm. Again the “in” or “mm” would be

transmitted as upper case letters (“IN” or “MM”) if the weld cycle had been

terminated because the system reached the distance setpoint. The distance

data is located at positions 18 through 22 and includes the “.” at position 19

(if English) or position 20 (if Metric). Another space character is at position

23. The “in”/“mm” label is located at positions 24 and 25 with a space at 26.

005647 00.48 sec

0.025 in

000130 J 045 %Pmax Alarms T:-- D:-- E:-- J06 -----

Item 4: Energy data is located at positions 27 through 32. The energy

number is the total Joules (watt-seconds) delivered to the load during the

last weld cycle. The following label “J” is an upper case letter (position 34)

that means this cycle was terminated because the energy setpoint was

achieved terminating the weld. If the cycle had not been terminated by

energy control, the label would have been a lower case character “j.” Space

characters are located at positions 33 and 35.

005647 00.48 sec 0.025 in

000130 J

045 %Pmax Alarms T:-- D:-- E:-- J06 -----

PRINT LINE OUTPUT DATA ITEMS

NOTE: Refer to page 29

for additional Print Line

Output.

Go To Top Of Document