Relationship of time, distance and energy settings – Sonics GXL User Manual
Page 20

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
I N S T R U C T I O N M A N U A L • M O D E L G X L P O W E R S U P P LY
19
The Alarm screen displays information about the alarm(s) that have been
triggered by the system encountering parameters outside of the specified
tolerance limits. The screen will indicate whether alarms occurred in Time,
Distance or Energy. If there are no alarms, dashes will display. If there are
alarms, an L (for Low limit, indicating that the low limit was violated) and/or
an H (for High limit, indicating that the high limit was violated) will display by
the applicable mode (time, distance or energy). When a new cycle begins,
the system will automatically clear the current alarm.
Counter Screen
The Counter screen displays information about the job number, the number
of cycles run to date, the customer resettable counter (CRC) and the
resettable alarm counter (RAC). The 2 resettable counters can be reset
whenever desired by pressing the Clear key when the counter screen is
displayed. (The keypad must be unlocked.)
RELATIONSHIP OF TIME, DISTANCE AND ENERGY
SETTINGS
Parameters can be set in the time, distance and/or energy menus. The
settings in all of these menus should be taken into account when you are
setting up a job since they do not function independently of each other and
a parameter in one menu can impact the effect of a parameter in another
menu.
For example, if you specify a weld time of 2 seconds, an energy setting of
2,000 joules, and clear any previous distance settings (so that only dashes
appear in the distance menu settings), the weld cycle will be terminated by
whichever of the 2 settings (Weld Time or Energy Setting) is reached first –
that is, either when ultrasonics have been applied for 2 seconds or when
energy equivalent to 2,000 joules has been delivered to the parts being
assembled. If 2 seconds is reached before 2,000 joules have been delivered,
the weld cycle will terminate regardless of the amount of energy delivered,
and vice versa.
The start-up ready screen which shows the last weld information will show a
flashing “sec” or “J” to indicate which setting was achieved first and thereby
terminated the weld cycle.
In the example above, if the weld time of 2
seconds is reached before 2000 joules have been delivered, the ready screen
J02
Cycles:
00,004,678
CRC: 000,062
RAC: 0,000