B. Hemisphere o-ring must rest evenly along canister/casting base o-ring
groove.
C. ST/CT/Small CSL: Hold canister housing against o-ring or sealing ring on
main filter head. Re-fasten wire-form clips or “claw” bolts.
D. Large CSL: Replace housing top plate. Feed T-bolts into corresponding
slots and tighten evenly around perimeter. Note: Do NOT over tighten!
E. VS/VL: Secure V-clamp by disconnecting hex nut or T-bolt portion and
placing V-clamp along the diameter of canister o-ring groove. Fasten T-
bolt and secure tightly. V-CLAMP LEGS MUST REST UNIFORMLY
ALONG ENTIRE O-RING GROOVE.
F. CSS: Reassemble top housing to bottom housing by aligning tabs and
turning into place.
Section D
MAINTENANCE RECOMMENDATIONS
1. Pressure drop readings are recommended to have an effective air filter.
Always document initial pressure drop during start-up when element is clean.
Replacement cartridge is needed when system experiences 10” to 15” / 250-
380mm H
2
O higher pressure drop above the initial reading. Refer to page 4
for instructions.
2. Always check replacement cartridge gaskets to insure they are adhered
uniformly along the end caps during handling. If not, contact Solberg
Manufacturing, Inc. immediately. Do not modify or change from Solberg
specified parts!
3. Always check inlets/outlets, element base and its components when replacing
element to insure cleanliness. Wipe clean if necessary.
4. Operate only when a proper seal exists.
5. VS/VL: Never operate without absolute assurance that V-clamp is secured
correctly along entire diameter of canisters. Check along V-clamp for wear.
Replace if any distortion occurs due to handling and usage.
SPARE PARTS
Contact your Solberg Representative for spare part model numbers.