B. Please check the listed steps prior to startup.
1. Check element to make sure it is seated properly on element
base or sealing surface.
*WARNING*
Failure to seat the element properly may result
in contaminant by-pass resulting in damage to
equipment.
2. Check element top plate or cover to make sure it is seated
properly on element.
3. Check housing cover that it is installed correctly onto housing.
4. Be sure all fasteners and hardware have been tightened.
*WARNING*
If the air flow is reversed through a Solberg
filter unit, be sure to check the element and
housing internals for damage. Failure to do so
may result in damage to equipment.
Section D
MAINTENANCE RECOMMENDATIONS
1. Pressure drop readings are recommended to have an effective air filter.
Always document initial pressure drop during start-up when element is clean.
Replacement cartridge is needed when
system experiences 10” to 15” / 250-
380mm H
2
O above drop above the initial reading. Refer to page 4 for initial
values.
2. Always check inlets/outlets, element base and its components when replacing
element to insure cleanliness. Wipe clean if necessary.
3. Operate only when a proper seal exists.