Slcr100 – Solberg SLCR-SLCRT(Pg.2-9) User Manual
Page 4
Solberg Manufacturing, Inc., 1151 Ardmore Itasca, IL 60143 USA
Ph: 630.773.1363 Fax: 630.773.0727 Email: [email protected] Web: www.solbergmfg.com
Page 4
No.
Filter Model
Number
Replacement
Element
Initial Delta P
Readings
1
2
3
4
5
Table 1
The model number designates the silencer type and connection size. For
example, the following part number identifies the product as being
a ‘SLCR’
design side channel blower silencer with a 1
” FPT connection size:
SLCR100
Note: The inlet connection greatly influences the overall pressure drop of the
filter system. To minimize the restriction contributed by a side channel blower
silencer, a velocity of 6,000 ft/min (10200m
3
/h) or less is suggested through the
outlet pipe. The table below lists the suggested flows based on pipe size:
Pipe Size
(inches)
Max Airflow
Pipe Size
(inches)
Max Airflow
1/2"
10 CFM 17m
3
/h
2"
135 CFM
230m
3
/h
3/4"
20 CFM 34m
3
/h
2 ½"
195 CFM
332m
3
/h
1"
35 CFM 60m
3
/h
3"
300 CFM
510m
3
/h
1 ¼"
60 CFM 102m
3
/h
4"
520 CFM
884m
3
/h
1 ½"
80 CFM 136m
3
/h
Table 3
*Note: This information is for general use only. A qualified engineer must properly design each system.
Connection
size and type
Silencer type:
SLCR
SLCRT