3. Removing element for service/maintenance.
A. Miniature Filter Silencer elements, models FS-(04, 05, 06, 07, 10, or 11),
should be free when housing tops are removed.
B. Clean sealing surfaces of housing and element so that they are free of dirt
or any other particulate.
*WARNING*
Failure to comply with these instructions
may result in system or equipment
contamination.
4. Securing Element.
Place new or cleaned element evenly in housing base. The wider end of
the element should be in line with the closing seam of the housing. Be
sure element seats properly in the housing base and there is no dirt or
particulate present on sealing surfaces. See Figure C.3.1.
*WARNING*
Defective installation may cause system or
pump contamination. Use only genuine
Solberg replacement parts.
5. Securing canister top to canister base.
A. Make sure all surfaces are free from dust and other particulate.
Figure C.3.1: Element sitting in housing
base.
Figure C.3.2: Element