*WARNING*
If the air flow is reversed through a Solberg
filter unit, be sure to check the element and
housing internals for damage. Failure to do so
may result in damage to equipment.
Section D
MAINTENANCE RECOMMENDATIONS
1. Pressure drop readings are recommended to have an effective air filter.
Always document initial pressure drop during start-up when element is clean.
Replacement cartridge is needed when
system experiences 10” to 15” / 250-
380mm H
2
O above drop above the initial reading. Refer to page 4 for initial
values.
2. Always check inlets/outlets, element base and its components when replacing
element to insure cleanliness. Wipe clean if necessary.
3. Operate only when a proper seal exists.