*WARNING*

If the air flow is reversed through a Solberg
filter unit, be sure to check the element and
housing internals for damage. Failure to do so
may result in damage to equipment.

Section D

MAINTENANCE RECOMMENDATIONS

1. Pressure drop readings are recommended to have an effective air filter.

Always document initial pressure drop during start-up when element is clean.
Replacement cartridge is needed when

system experiences 10” to 15” / 250-

380mm H

2

O above drop above the initial reading. Refer to page 4 for initial

values.

2. Always check inlets/outlets, element base and its components when replacing

element to insure cleanliness. Wipe clean if necessary.

3. Operate only when a proper seal exists.