Dhwg domestic hot water generator – Slant/Fin DHWG User Manual
Page 3
Dimensions:
Width = 17" Height = 12" Depth = 8
3
⁄
8
"
Specifications:
Weight (empty) = 21 lbs
Water content = 0.2 gallons
Piping connections = 3/4" nom. I.D. copper
Min. DHW flow = 0.3 gpm
Max. working pressure = 125 psi
Mounting to a Wall:
1. DHWG must be installed with water pipes at right or left
side of the unit (see figure 2).
2. Be sure that the wall is vertically plumb, and capable
of carrying the weight of the DHWG system and all
associated piping, when full of water. See the
specifications above.
3. The system may be mounted onto a combustible wall,
but the water piping must be kept a minimum of 1” away
from any combustible materials.
4. For stud type walls, be sure that there are studs available
in the desired location, and the appropriate fasteners are
utilized for the wood or metal stud type and weight
capacity.
5. For masonry walls, utilize anchors of the appropriate
design for the material and weight capacity.
6. Do not attempt to support the system with anchors driven
into sheetrock only.
3
DHWG Domestic Hot Water Generator
Table 1. DHWG pressure drop vs. flow
Table 2. DHWG temperature rise vs. water flow*
Figure 2.
Temp.
r
t –˚F
DHWG Flow Rate–GPM
LX-85A
Boiler
LX-90
Boiler
B-120A or LX-120
Boiler
LX-150
Boiler
B-200A
Boiler
100
80
70
60
55
1.4
1.8
2.1
2.5
2.8
1.6
2.0
2.3
2.7
3.0
2.0
2.5
3.0
3.5
4.0
2.3
3.3
4.0
4.5
5.0
2.5
3.75
4.75
5.75
6.5