0 powersave st commands, 1 command summary, 2 command descriptions – ScanTool STN11xx User Manual
Page 9: Slcs, Powersave st commands, Command summary, Command descriptions, Stslcs c, Stn11xx powersave

STN11xx
PowerSave
2.0 PowerSave
ST
Commands
The following sections describe the PowerSave ST commands. For brevity, the “ST” prefix is dropped in the
command summary, and throughout the text. However, the STN11xx only accepts the full command, including the
ST prefix. For example, the SLCS command must be entered as STSLCS.
2.1 Command Summary
Command Description
SLCS
Print active PowerSave configuration summary
Enter sleep mode with optional delay
Report last sleep/wakeup triggers
Set PWR_CTRL output polarity
UART sleep/wakeup triggers on/off
Set UART inactivity timeout
Set UART wakeup pulse timing
Voltage change wakeup trigger on/off
Set configuration of the voltage change wakeup trigger
Voltage level sleep/wakeup triggers on/off
Set configuration of the voltage level sleep trigger
Set configuration of the voltage level wakeup trigger
External sleep trigger on/off
Set polarity of the external sleep control input
Print external SLEEP input status
Set minimum active time for external sleep trigger before entering sleep
Set minimum inactive time for external sleep trigger before wakeup
2.2 Command Descriptions
SLCS
Print active PowerSave configuration summary.
This command prints only the currently active
configuration. Therefore, to see the native
configuration settings, ELM327 control mode must be
turned off by clearing the “master enable” bit of PP 0E
or turning off the PP 0E parameter. The device must
be reset for any PowerSave configuration changes to
take effect.
The configuration is printed in the following format:
CTRL MODE: <NATIVE/ELM327>
PWR_CTRL: LOW PWR = <LOW/HIGH>
UART SLEEP: <ON/OFF>, <timeout> s
UART WAKE: <ON/OFF>, <pulse min>-<pulse max> us
EXT INPUT:
<LOW/HIGH> = SLEEP
EXT SLEEP: <ON/OFF>, <LOW/HIGH> FOR <time> ms
EXT WAKE:
<ON/OFF>, <LOW/HIGH> FOR <time> ms
VL SLEEP:
<ON/OFF>, <</>>[!]<level> FOR <time> s
VL WAKE:
<ON/OFF>, <</>>[!]<level> FOR <time> s
VCHG WAKE: <ON/OFF>, [+/-][!]<change> IN <time> ms
See Table 1 for the detailed line-by-line description
of the configuration summary. The “Sec.” column of
Table 1 contains a reference to the relevant section of
this document.
Example:
CTRL MODE: NATIVE
PWR_CTRL: LOW PWR = LOW
UART SLEEP: OFF, 1200 s
UART WAKE: ON, 0‐30000 us
EXT INPUT: LOW = SLEEP
EXT SLEEP: OFF, LOW FOR 3000 ms
EXT WAKE: ON, HIGH FOR 2000 ms
VL SLEEP: OFF, <13.00V FOR 600 s
VL WAKE: OFF, >13.20V FOR 1 s
VCHG WAKE: OFF, 0.20V IN 1000 ms
or
VL SLEEP: OFF, <0x8C1 FOR 600 s
VL WAKE: OFF, >0x8E3 FOR 1 s
VCHG WAKE: OFF, 0x022 IN 1000 ms
STN11XXPSB www.ScanTool.net
9
of 13