Control Pad On The Dehumidifier
Display
Shows the set % humidity level from 35% to 85% or
auto start/stop time (0-24) while setting, then shows
the actual ( +/- 5% accuracy) room % humidity level
in a range of 30%RH (Relative Humidity) to 90%RH
(Relative Humidity).
Error Codes and Protection Code:
AS- Humidity sensor error--Unplug the unit for at least
5 minutes and plug it back in. If error repeats, call for
service.
ES- Temperature sensor error--Unplug the unit for at
least 5 minutes and plug it back in. If error repeats,
call for service.
P2- Bucket is full or bucket is not in the right
position-Empty the bucket and replace it in the right
position. Ensure float switch and foam are secured
properly in bucket.
E1- Unit malfunction--Unplug the unit for at least 5
minutes and plug it back in. If error repeats, call for
service.
EC- Unit malfunction--Please make sure whether the
environment temperature is suitable for the
stated temperature in the manual or not. If not, please
operate the unit under the stated temperature. If the
environment temperature is suitable for the stated
temperature, please call for service.
10
Other Features
Bucket Full Light
Glows when the bucket is ready to be emptied, or
when the bucket is removed or not replaced in the
proper position.
Auto Shut Off
The dehumidifier shuts off after 30 seconds when the
bucket is full, or when the bucket is removed or not
replaced in the proper position. When the humidity
setting is reached, the unit will be shut off
automatically. For some models, the fan motor will
continue operating.
Auto Defrost
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue to
run until the frost disappears. The unit will restart on
its own.
Safety Feature
After the unit has stopped, it cannot resume operation
in the first 3 minutes afterwards. This is to protect the
unit. Operation will automatically start after 3 minutes.
Check Filter Feature
The system starts to log the time once the fan motor
operates. The check filter light will be lit up only when
the accumulated operation time achieves 250 hours
or more. The Reset light (Clean Filter indicator light)
flashes one time per second. After cleaning the air
filter, press the Filter pad and the Reset light (Clean
Auto-Restart
If the unit breaks off unexpectedly due to a loss of
power, it will restart with the previous function setting
automatically when the power resumes.
Setting the Timer
When the unit is on, press the Timer button; the Timer
Off indicator light illuminates. It indicates the Auto Stop
program is initiated. Press it again and the Time On
indicator light illuinates. It indicates the Auto start is
initiated.
Press or hold the UP or DOWN pad to change the
Auto time by 0.5 hour increments. up to 10 hours, then
at 1 hour increments up to 24 hours. The control will
count down the time remaining until start.
The selected time will register for 5 seconds and the
system will automatically revert back to display the
previous humidity setting.
When the Auto start and Auto stop times are set,
within the same program sequence, TIMER ON OFF
indicator lights illuminate identifying both ON and OFF
times are now programmed.
Turning the unit ON or OFF at any time or adjusting
the timer setting to 0.0 will cancel the Auto Start/Stop
function.
When LED display window displays the code of P2,
the Auto Start/Stop function will also be cancelled.