Cooper Lighting RD Series User Manual
Cooper lighting - sure-lites, Rd series, Rlm series
606
EMERGENCY LIGHTS
Architectural
COOPER LIGHTING
(1)
Consult your Cooper Lighting Representative.
(2)
Provision for one meter only.
COOPER LIGHTING - SURE-LITES
®
D I M E N S I O N S
• Dual-voltage input
120/277VAC, 60Hz
• 20 gauge die-formed steel
housing with white powder
coat finish
• Heads match housing
finish
• Knockout, conduit or cord
set
• Supplied with hanger bars,
T-Bar clips
• Single modular electrical
connector
• Remote capability
• Line-latching, Solid-State
voltage limited charger,
Solid-State switching,
low- voltage disconnect,
brownout circuit,
overload/short-circuit
protection, test
switch/power indicator
light
• UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA,
most state and local codes
D E S C R I P T I O N
The RD Series is a recessed
emergency lighting system
designed for locations where
aesthetics are of utmost
importance. The housing is
fully recessed in dry wall or
grid ceiling installations.
Designer pinchback heads
rotate 358° and swivel 90° to
0°. Ideal for commercial and
institutional environments
where easy recessed
installation and minimal
maintenance are desired.
The RLM Series is a recessed
system packaged in an
attractive flame-resistant
metal housing. It is the unit
of choice for installations
where a recessed product is
desired and the size and cost
of emergency lighting must
be kept to a minimum
without sacrificing
dependability or light output.
RD SERIES
Tw o I n j e c t i o n M o l d e d
T h e r m o p l a s t i c H e a d s
RD1
SLC
6
18
15
10
8
Tungsten Halogen
6
29-12
RD3
SLC
6
27
24
18
14
Tungsten Halogen
12
29-66
RD4
SLC
12
54
-
-
-
Incandescent
9
029-86
RD6
SNC
6
15
12
8
6
Tungsten Halogen
6
29-12
RD7
SNC
6
24
18
12
10
Tungsten Halogen
12
29-66
RLM1
SLC
6
10.8
7.2
-
-
Incandescent
5.4
29-121
RLM2
SLC
6
18
15
10
8
Incandescent
9
29-84
RLM3
SLC
6
27
24
18
14
Incandescent
9
29-84
RLM4
SLC
12
54
-
-
-
Incandescent
9
029-86
RLM8
SNC
6
15
12
8
-
Incandescent
7.2
29-88
RLM9
SNC
6
24
18
12
10
Incandescent
7.2
29-88
O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : R D 1 V
5 1/8"
(130mm)
10 1/4" (260mm)
12 7/8" (327mm)
3 1/2"
(89mm)
7" max.
(178mm)
6"
(152mm)
(RD4 Only)
8 1/4"
(210mm)
9 1/4" (235mm)
6 1/4" (159mm)
4 5/8"
(118mm)
Options
(Add as suffix)
A=Ammeter
(2)
SD=Self-Diagnostics
TDM=Time Delay Monitor
V=Voltmeter
(2)
Alternate Lamps
(1)
Other Options
(1)
Model Number
RD1
RD3
RD4
RD6
RD7
RLM1
RLM2
RLM3
RLM4
RLM8
RLM9
Accessories
(Order separately)
WG2 =Wire Guard
WG7 =Wire Guard
VS=Choose polycarbonate
vandal shield desired
from accessories
sheet
E n e r g y D a t a
Input Current (Max.):
Model No.
120V
277V
RD1, RD3
.12A
.05A
RD4, RLM4
.30A
.13A
RD6
.06A
.03A
RD7
.07A
.04A
RLM1, RLM2, RLM3
.12A
.05A
RLM8
.06A
.03A
RLM9
.07A
.04A
E L E C T R I C A L R A T I N G S
Rated Wattage
to 87 1/2% of rated D.C. Voltage
Lamp Information
Model
Battery
DC Voltage
1 1/2 hours
2 hours
3 hours
4 hours
Type
Wattage
Number
SLC=Sealed Lead Calcium Battery
SNC=Sealed Nickel Cadmium Battery
RLM SERIES
Tw o H i g h - I m p a c t
T h e r m o p l a s t i c H e a d s
R e c e s s e d H o u s i n g
E M E R G E N C Y L I G H T
9 1/4" (235mm)
6 1/4"
(159mm)
12 7/8" (327mm)
10 1/4" (260mm)
9 1/4"
(235mm)
3 1/2"
(89mm)
5 1/8"
(130mm)
8 1/4"
(210mm)
6"
(152mm)
(RLM4 Only)
4 5/8"