Compex Systems SGX3226 User Manual
Page 86
Appendix I
Panel Views and Descriptions
76
Features
Status and Indication
5 Redundant
Power
Socket
Additional Power Socket (Optional). With this RPS,
Compex SGX3226 still able to operate even Primary Power
Supply is down.
6
Reset Button
By pushing the reset button once,
• The switch will clear all previous temporary error
• P.O.S.T. will activate self-diagnostic program to check
any error.
• Switch would be re-configured with settings stored in
non-volatile flash memory.
7
Mute Button
To toggle the On or Off Switch of the Alarm Buzzer
Steady Green
Normal Operation
8
System Status LEDs
Steady Red
POST is running Self-diagnostic after reset
or power up
Steady
Green Power supply is working in normal
condition.
9 Power
LED
Steady Red
• Power supply is faulty.
• Power supply fault occurs.
Steady Green
Primary power supply is working and RPS
is in standby mode.
Steady Red
Primary power supply is faulty and RPS is
in working condition.
When the primary power resume its
electrical supply, RPS LED will still
remains Steady Red unless you reboot
your switch, then RPS LED will turn to
Steady Green.
10
Redundant PS LED
Off
Both primary power supply and RPS
turned off.