Section 2. ET Tower Installation

DANGER: Do not install near power lines. If any part of the tower comes in contact with
power lines you could be KILLED. Contact local utilities for the location of buried utility
lines before digging or driving grounding rods.

CAUTION: Do not fit the 3 meter ET Tower sections together until the appropriate time.
Once attached, they cannot be detached.

The ET Tower provides a support structure for mounting the ET101 and ET106 weather
station components. Figure 2.1-1 shows a typical ET Tower installation option. The
tower is designed to withstand winds of 100 mph. The lightning rod assembly is attached
after the instrumentation enclosure is installed (Section 3.1).

Transformer

User Supplied
Junction Box

110 VAC

16 VAC
Power

Valve Box

Communications
Line

Direct Bury
Splices

Concrete
Base

Ground
Rod

ET Tower

FIGURE 2.1-1. ET Tower Installation

2.1 Base Installation

2.1.1 Supplied Components

(3) ½ inch L-Bolts
(9) ½ inch Nuts
(1) Anchor Template

Refer to Section 1 for components supplied by installer.