Table 1C — 40RMS Physical Data, English
UNIT 40RMS
008
010
012
014
016
024
028
034
NOMINAL CAPACITY (Tons)
7
1
⁄
2
8
1
⁄
2
10
12
1
⁄
2
15
20
25
30
OPERATING WEIGHT (lb)
Base Unit
390
391
391
661
677
683
1035
1042
Plenum
97
97
97
140
140
140
180
180
FANS
Qty...Diam. (in.)
1...15
1...15
1...15
2...15
2...15
2...15
2...18
2...18
Nominal Airflow (cfm)
3000
3400
4000
5000
6000
8000
10,000
12,000
Airflow Range (cfm)
2250-3750
2250-4250
3000-5000
3750-6250
4500-7500
6000-10,000 7500-12,500 9000-15,000
Nominal Motor Hp
(Standard Motor)
208/230-1-60
2.4
2.4
—
—
—
—
—
—
208/230-3-60 and 460-3-60
2.4
2.4
2.4
2.9
3.7
5.0
7.5
10.0
575-3-60
2.0
2.0
2.0
3.0
3.0
5.0
7.5
10.0
230-3-50 and 400-3-50
2.4
2.4
2.9
2.9
2.9
5.0
7.5
10.0
Motor Speed (rpm)
208/230-1-60
1725
1725
—
—
—
—
—
—
208/230-3-60 and 460-3-60
1725
1725
1725
1725
1725
1745
1745
1745
575-3-60
1725
1725
1725
1725
1725
1745
1755
1755
230-3-50 and 400-3-50
1425
1425
1425
1425
1425
1425
1425
1425
CHILLED WATER COIL
Enhanced Copper Tubes, Aluminum Sine-Wave Fins
Max Working Pressure
(psig)
435
Face Area (sq ft) — Upper
8.3
9.0
4.9
8.3
8.3
11.0
12.4
15.5
Face Area (sq ft) — Lower
—
—
4.9
5.5
8.3
8.3
12.4
12.4
Rows...Fins/in.
3...15
STEAM COIL
Max Working Pressure
(psig at 400 F)
175
Total Face Area (sq ft)
6.67
6.67
6.67
13.33
13.33
13.33
15.0
15.0
Rows...Fins/in.
1...9
1...9
1...9
1...10
1...10
1...10
1...10
1...10
HOT WATER COIL
Max Working Pressure
(in. wg)
150
Total Face Area (sq ft)
6.67
6.67
6.67
13.33
13.33
13.33
15.0
15.0
Rows...Fins/in.
2...8.5
2...8.5
2...8.5
2...8.5
2...8.5
2...8.5
2...12.5
2...12.5
Water Volume
(gal)
8.3
13.9
14.3
(ft
3
)
1.1
1.85
1.90
PIPING CONNECTIONS,
Quantity...Size (in.)
Chilled Water — In
1...1
3
⁄
8
ODF 1...1
3
⁄
8
ODF 2...1
3
⁄
8
ODF 2...1
3
⁄
8
ODM 2...1
3
⁄
8
ODM 2...1
3
⁄
8
ODM 2...2
1
⁄
8
ODM 2...2
1
⁄
8
ODM
Chilled Water — Out
1...1
3
⁄
8
ODF 1...1
3
⁄
8
ODF 2...1
3
⁄
8
ODF 2...1
3
⁄
8
ODM 2...1
3
⁄
8
ODM 2...1
3
⁄
8
ODM 2...2
1
⁄
8
ODM 2...2
1
⁄
8
ODM
Steam Coil, In (MPT)
1...2
1
⁄
2
1...2
1
⁄
2
Steam Coil, Out (MPT)
1...1
1
⁄
2
1...1
1
⁄
2
Hot Water Coil, In (MPT)
1...1
1
⁄
2
1...1
1
⁄
2
1...2
Hot Water Coil, Out (MPT)
1...1
1
⁄
2
1...1
1
⁄
2
1...2
Condensate (PVC)
1...1
1
⁄
4
ODM/1 IDF
FILTERS
Throwaway — Factory Supplied
Quantity...Size (in.)
4...16 x 24 x 2
4...16 x 20 x 2
4...16 x 24 x 2
4...20 x 24 x 2
4...20 x 25 x 2
Access Location
Either Side