Т³гж 4, C223, Way, 3-way crossovers – OmniSistem Beta 3 – C223 User Manual
Page 4
2-WAY, 3-WAY CROSSOVERS
C223
Mono 3-Way Mode
In 3-way mono operation the controls are marked ABOVE the horizontal Red line. Front panel controls
not described in this section are not active in mono 3-way mode. LEDs are disabled for controls which
are nonfunctional in this mode.
INPUT GAIN
LOW CUT
LOW/MID
X10 LED
MID/HIGH
X10 LED
LOW OUTPUT
PHASE INVERT
MID OUTPUT
PHASE INVERT
HIGH OUTPUT
PHASE INVERT
MONO
Controls the INPUT level with +/- 12dB of gain.
Switch for selecting the 40Hz high pass filter. An LED indicates the selection.
Selects crossover point between the LOW and MID frequencies.
Indicates that the LOW/MID crossover range is 450Hz to 9.6kHz.
Selects the crossover point between MID and HIGH frequencies.
Indicates that the MID/HIGH crossover frequency range is 450Hz to 9.6kHz.
Controls the Low Frequency output level with a range of to +6dB.
Controls the Mid Frequency output Level with a range of to +6dB.
Controls the HIGH frequency output level with a range of to +6dB.
LED indicating mono mode operation.
[1]
[9]
[2]
[10]
[6]
[16]
[3]
[11]
[7]
[17]
[8]
[18]
[13]
Switch for reversing the polarity on the high output. An LED indicates that the phase
is reversed.
Switch for reversing the polarity on the low output. An LED indicates that the phase
is reversed.
Switch for reversing the polarity on the Mid Output. An LED indicates that the phase
is reversed.
3