Light output, Troubleshooting – OmniSistem PR Pilot 575 Wash User Manual
Page 12
![background image](/manuals/700574/12/background.png)
PILOT WASH 575 EN.doc
12/16
colour filters or housing of the apparatus
LIGHT OUTPUT
35° DIAMETER (m)
3
5
°
1
5
°
9800
2350
1.3
5
3.15
4m
15° DIAMETER (m)
DISTANCE (m)
0
0
0
5m
15° ( lux)
2m
2m
0m
4m
3m
1m
3m
1m
5m
35° ( lux)
9.45
3.94
15
2.63
6.3
10
5.26
12.6
20
610
2400
1090
140
588
90
25
15.7
6.58
65
390
PROBLEM
POSSIBLE CAUSE
ACTION
The
projector
doesn’t
switch on
The power supply is not
present
The lamp doesn’t work
Check the fuse on the power
socket.
Replace the lamp.
The lamp comes on but
the projector doesn’t
respond to the controller
Wrong DMX configuration
and/or start address
Defective DMX cable
Make sure that the projector is
correctly configurated.
Replace or repair the DMX
cable.
The
projector
only
functions intermittently
The fan has failed
Make sure the fan is working
and not dirty.
Defective projection
The lens is broken
Dust or grease on lenses
Check the lenses are not
broken.
Remove dust or grease from
the lenses.
The projected image
appears to have a halo
Installation of the lamp is
not correct
Dust or grease
contamination on the
optics.
Make sure the lamp is installed
correctly.
Carefully clean the optical
group lenses and the projector
components.
The beam appears dim
Dust or grease
contamination on the
optics.
The lamp is at the end of
its life
Check the optics is clean.
Replace with a new lamp of the
specified type and rating.
TROUBLESHOOTING