Century Spot adopts international standard DMX 512 protocol. You may control many luminaires
via controller. When in controller mode, the function code 1 and 2 of all luminaires should be set
to “n”, and each apparatus should have specific address to receive the signal from the controller.
Century Spot has 6 channels. So, in controller mode, the address of 1

st

luminaire is 001; 2nd, 007;

3

rd

, 013; 4

th

, 019; etc. Please follow the formula: address of n

th

luminaire=6 x (n-1) + 1.


Connect the controller’

s output to the 1

st

luminaire’

s input, and connect the 1

st

luminaire’

s output

to the 2

nd

luminaire’

s input. The rest may be connected in the same way. Eventually connect the

last luminaire’

s output to a DMX terminator as shown below.

DMX CONTROL CHANNEL FUNCTIONS


The Century Spot has 6 channels. They are shown in the following table.

CHANNELS

DMX VALUE

DESCRIPTION

1 Shutter

000-255

Shutter to open continuous change

2 Cyan

000-255

White to cyan continuous change

3 Yellow

000-255

White to yellow continuous change

4 Magenta

000-255

White to magenta continuous change

5 Focus

000-255

Focusing from big to small

000-249

Reserved

6 Control

250-255

Reset

CONTROLLER MODE – DMX 512 OPERATION