Controller mode – dmx 512 operation, Dmx control channel functions – OmniSistem PR Century Spot User Manual
Page 8
Century Spot manual_Last Revision_en.doc
8/14
Century Spot adopts international standard DMX 512 protocol. You may control many luminaires
via controller. When in controller mode, the function code 1 and 2 of all luminaires should be set
to “n”, and each apparatus should have specific address to receive the signal from the controller.
Century Spot has 6 channels. So, in controller mode, the address of 1
st
luminaire is 001; 2nd, 007;
3
rd
, 013; 4
th
, 019; etc. Please follow the formula: address of n
th
luminaire=6 x (n-1) + 1.
Connect the controller’
s output to the 1
st
luminaire’
s input, and connect the 1
st
luminaire’
s output
to the 2
nd
luminaire’
s input. The rest may be connected in the same way. Eventually connect the
last luminaire’
s output to a DMX terminator as shown below.
DMX CONTROL CHANNEL FUNCTIONS
The Century Spot has 6 channels. They are shown in the following table.
CHANNELS
DMX VALUE
DESCRIPTION
1 Shutter
000-255
Shutter to open continuous change
2 Cyan
000-255
White to cyan continuous change
3 Yellow
000-255
White to yellow continuous change
4 Magenta
000-255
White to magenta continuous change
5 Focus
000-255
Focusing from big to small
000-249
Reserved
6 Control
250-255
Reset
CONTROLLER MODE – DMX 512 OPERATION