Structure fitting the lamp power supply - mains – OmniSistem PR Century Spot User Manual
Page 4
Century Spot manual_Last Revision_en.doc
4/14
Caution:
For the safety reason, remove the sponge between the colour filters before the 1
st
application of luminaire.
Position the projector-head facing the sky and lock it via locking knob.
Remove the projector-head cover by loosening the 4 retaining clips.
Open the dichroic-colour-filter bracket by undoing the 2 M6 knurled-screws.
Insert the lamp in the lamp-holder, and ensure PST (pumping stem tip off) on the lamp is at a right
angle (90°) to the beam path. Don’
t touch the bulb by bare hand.
Close the dichroic-colour-filter bracket and install projector-head cover. Make sure that all screws
and retaining clips are tightened.
Note:
The HMI series are high-pressure lamps with external igniters (
). Care should always be
taken when handling these lamps. Always read the manufacturers "Instructions for use" enclosed
with the lamp.
Use the plug provided to connect the mains power to the projector paying attention to
the voltage
and frequency marked on the panel of the projector. It is recommended that each projector be
supplied separately so that they may be individually switched on and off.
STRUCTURE
FITTING THE LAMP
POWER SUPPLY - MAINS