beautypg.com

Trouble shooting – O.S. Engines 12TZ(P) User Manual

Page 14

background image

26

TROUBLE SHOOTING

Symptom

Cause

Corrective action

Engine fails to fire.

Fuel tank is empty.
Fuel not reaching the engine.

Fill the tank with fuel and repeat
Priming procedure.

Glowplug element is burnt out.
Glowplug battery discharged

Replace glowplug.

Recharge or replace the battery.

Clogged fuel filter

Air cleaner and silencer inside is dirty.

Clean or replace fuel filter.

Replace cleaner element and clean inside silencer.

Over priming

Remove glowplug and pump excess fuel.

Fuel tubing is disconnected.

Connect fuel tubing securely.

Fuel tubing is kinked, split or has a hole.

Check the tubing carefully and replace if necessary.

Incorrect servo linkage

Connect correctly after setting servo at neutral.

Reverse rotating direction of starter box.

Mare sure it rotates counter clockwise seen
from crankshaft side.

27

Symptom

Cause

Corrective action

Engine fires intermittently but does not run.

Insufficient fuel in the tank.

Fill the tank with fuel.

Deteriorated glowplug

Replace glowplug.

Clogged fuel filter

Air cleaner and silencer inside is dirty.

Clean or replace fuel filter.

Replace cleaner element and clean inside silencer.

Engine overheated

Wait until engine is cool.

Incorrect clutch release

Adjust the tension of clutch spring.

Starting battery disconnected too soon.

Do not disconnect plug battery and wait until
r.p.m. become stable.

Vibration causing air bubbles in fuel.

Install "O" rings to the tank screws to
prevent bubbles.