页 11, Test result 6 – NOYAFA NF-8208 User Manual
Page 11
it will display as follows to indicate the measurement is being undertaken:
----T e s t i n g ----
12345678...
Note:In view of different technical parameters in various brand cables, the
user should apply the tester dynamic calibration function before length
measurement (Refer to the details herein).
Test Result 1: Short circuit (SHORT)
It will display as follows if there is any short circuit in cable or terminal:(12
short circuit in the sample)
Short:
12
Test Result 6:
Open circuit in the middle of cable
It will display wiring diagram (WIREMAP) as follows if there is an open
circuit in the middle of the cable:
Wire map:fail
R: 12345678 id1
Iixiiiii
M: 12345678
"|” line "3" pin location displays "x", it indicates an open circuit in the middle of
"3" pin cable. (The open circuit should be located within 10%-90%cable length
if it is measured from the near-end plug.) For further locating open circuit, the
function (PAIR & LENGTH) of the tester could used as detailed hereinafter.
Your excellent helper in cable test!
08