beautypg.com

页 11, Test result 6 – NOYAFA NF-8208 User Manual

Page 11

background image

it will display as follows to indicate the measurement is being undertaken:

----T e s t i n g ----
12345678...

Note:In view of different technical parameters in various brand cables, the

user should apply the tester dynamic calibration function before length

measurement (Refer to the details herein).

Test Result 1: Short circuit (SHORT)

It will display as follows if there is any short circuit in cable or terminal:(12

short circuit in the sample)

Short:
12

Test Result 6:

Open circuit in the middle of cable

It will display wiring diagram (WIREMAP) as follows if there is an open

circuit in the middle of the cable:

Wire map:fail

R: 12345678 id1

Iixiiiii

M: 12345678

"|” line "3" pin location displays "x", it indicates an open circuit in the middle of

"3" pin cable. (The open circuit should be located within 10%-90%cable length

if it is measured from the near-end plug.) For further locating open circuit, the

function (PAIR & LENGTH) of the tester could used as detailed hereinafter.

Your excellent helper in cable test!