NORAC UC5-BC-SC02 User Manual
Page 27
23
17. Disconnect the connection where the flex line and steel line meet. Be sure this is the line
that connects to the gold accumulator block at the tilt cylinder.
18. Install a 6FJXR 6MJT fitting (F04) onto the steel line and then attach the flex line to the tee
fitting. Install hose H03 onto the tee fitting.
Figure 25: Tee in the “B” (Raise) Line
19. Remove the 12MB 12MB orifice fitting installed between the gold accumulator block and tilt
cylinder. Replace the fitting with the 12MB 12MB fitting (F08).
Figure 26: Fitting Between the Cylinder and Accumulator Block to be Replaced
20. Remove the accumulator from the block. Remove the 8MB 8MB fitting from the gold block.
Turn the fitting over and reinstall it into the block so the adjustable end, where the
accumulator will thread on, is facing up.
21. Install the orifice insert (F09) inside the accumulator. Reattach the accumulator with the
orifice inside.
Figure 27: Orifice Insert Installed in the Accumulator
Flex Line to
Accumulator
Steel Line
NORAC
“B” Line
Replace This
Fitting with F08
Flip This Fitting