Figure 18: Valve Module Bracket Installation

5. Connect the valve module CANbus to cable C01 from the control module. Route cable

C02 from the other CANbus connector to the input module.

6. With the valve module securely mounted to the valve block, connect the valve cables (C10),

to the valve coils. Insert the 2-pin plugs (P01) into the unused 2-pin connectors on the
valve module.

7. Connect the temperature probe to the valve block using the supplied 3/8” x 1/2” hex bolt.

Figure 19: Valve Module - Valve Coil Connections

Tank Port

Pressure Port

Sense Port

Left Tilt Ports

Right Tilt Ports