beautypg.com

3 hydraulic plumbing – NORAC UC5-BC-RG07 User Manual

Page 28

background image



25

10.3 Hydraulic Plumbing

From this point on in the installation the booms will be inoperative until the

hydraulics are fully installed.

1. After the NORAC valve is mounted, the hydraulic hoses and fittings can be plumbed. The

plumbing for the hydraulic circuit is shown schematically in Figure 3.

2. Disconnect the tilt “raise” lines from the sprayer valve block and insert the two tees (F04)

between the hoses and the valve block.

3. Connect two hydraulic hoses (H01) from the free ends of the tees to the “B” ports on the

NORAC valve block. Connect the 90 degree end of the hoses to the NORAC valve block.

4. Disconnect the pressure and tank lines from the sprayer valve block and insert the two tees

(F04) between the hoses and the valve block.

5. Connect two hydraulic hoses (H01) from the free ends of the tees to the pressure and tank

port on the NORAC valve block. Connect the 90 degree end of the hoses to the NORAC
valve block.

6. There must be no other orifices in the hydraulic circuit between the NORAC valve block

and the tilt cylinders.

This manual is related to the following products: