3 input module – NORAC UC5-BC-RG07 User Manual
Page 24
21
8.3 Input Module
1. Install the input module (E03) on the sprayer near the NORAC valve block. Secure it to
the boom using cable ties or optional brackets.
2. Connect the free end of the CANbus cable (C02) from the valve module to the input
module.
3. Insert the 12 pin plug (P02) into the OEM 3 connector on the end of the input module.
4. Connect the 12 pin connector on the tilt interface cable (C20) to the Thru 2 connector on
the side of the input module.
5. Insert the other connectors on C20 into the tilt connectors on the Rogator valve block.
Figure 21: Input Module Connections
6. Connect the 12 pin connector on the main lift interface cable (C21) to the Thru 1
connector on the side of the input module.
7. Insert the other connectors on C21 into the main lift connectors on the Rogator solenoids.
8. Connect the male and female “Aux 1” connectors together. Connect the male and female
“Aux 2” connectors together.