beautypg.com

8 connecting the sensors to the canbus – NORAC UC5-BC-GN02 User Manual

Page 17

background image



14

8 Connecting the Sensors to the CANbus

1. Route cable C03 from the input module to the 3-way coupler (E10).

2. Fasten the 3-way coupler to the boom with cable ties.

3. Connect two cables (C05) to the 3-way coupler and route along the booms to the wing

sensors. Follow existing cables and hoses to be sure the cable will not be pinched or
stretched.

Figure 12: UC5 Module Locations and Cable Connections

4. At the sensor brackets, attach a 2-way coupler with terminator (E20) to the sprayer boom.

The 2-way coupler with terminator is the white two way coupler. Plug the sensor and the
CANbus cable into the 2-way coupler.

Ensure that all unused connectors are plugged with the plugs provided.